ISOLATED DC/DC CONVERTERS  
					48 Vdc Input 12 Vdc /12 A Output  
					0RCY-C2T12x  
					RoHS Compliant  
					Rev.B  
					
					
					
					
					
					
					
					Isolated  
					High Efficiency  
					
					
					
					
					
					
					Output Over-Voltage Shutdown  
					OCP/SCP  
					Over Temperature Protection  
					Output Voltage Trim  
					Remote On/Off  
					Positive/Negative Remote Sense  
					High Power Density  
					Fixed Frequency (300 kHz)  
					Low Cost  
					Input Under-Voltage Lockout  
					Basic Insulation  
					Description  
					The 0RCY-C2T12x is isolated dc/dc converter that operates from a nominal 48 Vdc source. This unit will provide  
					up to 144 W of output power from a nominal 48 Vdc input. This unit is designed to be highly efficient and low cost.  
					Features include remote on/off, over current protection and under-voltage lockout. This converter is provided in an  
					industry standard eighth brick package.  
					Part Selection  
					Output  
					Input Voltage  
					Max. Output  
					Current  
					Max. Output  
					Power  
					Typical  
					Efficiency  
					Model Number  
					Active High  
					Model Number  
					Active Low  
					Voltage  
					12 Vdc  
					48 Vdc  
					12 A  
					144 W  
					93%  
					0RCY-C2T120  
					0RCY-C2T12L  
					Notes: 1. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.  
					2. Add “G” suffix at the end of the model number to indicate Tray Packaging.  
					Absolute Maximum Ratings  
					Parameter  
					Input Voltage (continuous)  
					Input Voltage (Transient)  
					Remote On/Off  
					Min  
					-0.3 V  
					-
					Typ  
					Max  
					80 V  
					Notes  
					-
					-
					-
					-
					-
					100 V  
					18 V  
					100 mS  
					-0.3 V  
					-40 C  
					-55 C  
					Ambient Temperature  
					Storage Temperature  
					85 C  
					125 C  
					Input Specifications  
					Parameter  
					Min  
					Typ  
					Max  
					Notes  
					Input Voltage  
					36 V  
					48 V  
					75 V  
					Input Current (full load)  
					Input Current (no load)  
					Remote Off Input Current  
					-
					-
					-
					-
					5.0 A  
					120 mA  
					15 mA  
					60 mA  
					10 mA  
					Input Reflected Ripple Current  
					(rms)  
					With simulated source impedance of 10 uH,  
					5Hz to 20MHz. Use a 100 uF/100 V  
					electrolytic cap with ESR=1 ohm max, at  
					200 KHz@25°C.  
					-
					5 mA  
					10 mA  
					Input Reflected Ripple Current  
					(pk-pk)  
					I2t Inrush Current Transient  
					-
					-
					25 mA  
					40 mA  
					0.1 A2s  
					0.5 A2s  
					Turn-on Voltage Threshold  
					Turn-off Voltage Threshold  
					33 V  
					31 V  
					34 V  
					32 V  
					36 V  
					34 V  
					Note: All specifications are typical at 25 C unless otherwise stated.  