8
0RCY-F0S10x
9. POWER GOOD
Note:
1. The Power Good signal is a non-latching open-collector output that is Low during normal operation and is pulled High when any of the following
conditions occur:
• Over-Temperature
• Over-Current
• Vout is outside of the DC Output Band while Vin is within the Vin Operating Range
• Vin is within the Vin Operating Range but the unit is not operating (to determine if 1 Unit used in a parallel
configuration is not operating)
• Vin is outside of the Vin Operating Range
2. The Power Good signal is referenced to Vout(-).
PARAMETER
DESCRIPTION
MIN
8.2
TYP
MAX
8.6
UNIT
Output Voltage Low (trigger limits)
Output Voltage High (trigger limits)
-
-
V
V
12.6
13.1
Input Voltage Low (trigger limits)
Rising
Input Voltage High (trigger limits)
Rising
PG signal indicats good when Vin is within
operating range and indicats bad ~20ms before
unit is shut-down due to UV or OV
42.5
58
-
-
45
61
V
V
Hysteresis
-
1
-
-
V
V
High State Voltage
0
5.5
High State Leakage Current (into
Pin)
0
-
10
µA
Low State Voltage
0
0
0
-
-
-
0.8
5
V
Low State Current (into Pin)
mA
ms
Duration between the fault occurring and the
Power-Good Signal de-asserting
Power Good Signal De-assert
Response Time
3
Power Good Signal Assert Response
Time
Duration between unit powering up with no
faults and the Power Good Signal asserting
Duration the Power-Good signal stays de-
asserted if a transient fault occurs
0
-
3
ms
ms
Power Good Signal Duration
200
600
10degC
below
OTP
For OT Warning, the PG signal will toggle as an
impulse wave.
Over Temperature Warning
oC
threshold
OT Warning PG signal frequency
OT Warning PG signal duty cycle
90
100
50
110
kHZ
%
47.5
52.5
tech.support@psbel.com