AZF-60 SERIES
AC/DC POWER MODULE 60W
Output Specifications
Parameter
Conditions
Min.
---
Typ.
1.0
0.2
0.5
2.0
1.0
10
Max.
2.0
1.0
1.0
3.0
1.3
---
Unit
%
Output Voltage Accuracy
Line Regulation
Vin=Min. to Max.
Iout=Min. to Max.
---
%
Load Regulation
---
%
5.1VDC Output Models
Other Output Models
---
%VPP of Vo
%VPP of Vo
%Inom.
% of Vo
%
Ripple & Noise (20MHz)
---
Minimum Load
---
Over Voltage Protection
Transient Response Deviation
Temperature Coefficient
Overshoot
Zener diode clamp
---
120
3
---
(Iout=100% to Iout=50%)
6
---
---
0.02
---
---
%/℃
5
% Vout
Foldback, auto-recovery
Current Limitation
105
---
---
%Inom.
(long term overload condition may cause damage)
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
General Specifications
Parameter
Conditions
Input to Output, 60 Seconds
500 VDC
Min.
3000
100
Typ.
---
Max.
---
Unit
VACrms
MΩ
I/O Isolation Voltage
I/O Isolation Resistance
Switching Frequency
Hold-up Time
---
---
---
100
20
---
KHz
---
---
ms
MTBF (calculated)
EMC Emission
MIL-HDBK-217F@25℃, Ground Benign
Conducted and radiated
Standard
125,000
---
---
Hours
EN 55011 class B, EN 55022 class B, FCC part 15 class B
Specification Requirement
Air 8KV Cont. 4KV
Performance Criteria
B
A
B
B
EN61000-4-2
EN61000-4-3
80~1000MHz, 10V/m 80% AM, 1KHz modulation
AC port 2KV DC, SL, TL 2KV not less than 1 min.
1.2/50µS(8/20µS) AC dif. 1KV DC 0.5KV
0.15~80MHz, 10Vrms (functional earth ports included)
80% AM, 1KHz modulation
EN61000-4-4
EMC Immunity according
EN61000-6-1
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
B
A
B
C
50Hz/60Hz, 30A/m
30%, 10ms
60%, 100ms, 95%, 5000ms
Protection Class II
Safety Approvals
According IEC/EN 60536
cUL/UL 60950-1,IEC/EN 60950-1
(UL508 for models with order code suffix ICE only)
Input Fuse
All Models
Built-in Fuse
6A / 250VAC
External Fuse (Recommended)
3A Slow – Blow Type
Environmental Specifications
Parameter
Conditions
Temperature Range (operational)
Power Derating
Ambient
-10℃
+70℃
2.25W / ℃
2.25W / ℃
+85℃
+50℃ to +70℃
+40℃ to +70℃
Power Derating (5.1Vout)
Storage Temperature Range
Over Temperature Protection
Cooling
-40℃
at 90℃ (automatic recovery at 67℃)
Free-Air convection
---
Humidity (non condensing)
95 % rel. H
Notes
1
2
3
All specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage and after warm-up time rated output current unless otherwise noted.
Ripple & Noise measurement bandwidth is 0~20 MHz
These power modules require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage the power
supplies however they may not meet all listed specifications.
4
5
6
Other input and output voltage may be available, please contact factory.
Long term short circuit operation may cause damage to the unit.
Specifications are subject to change without notice
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2013/02/25 REV:11 Page 2 of 4