CORCOM Product Guide  
					Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for  
					General Purpose Applications for UL544 Health Care Equipment  
					J Series  
					Front View, All Models  
					6J4/6J4-2  
					Terminal View  
					UL Recognized  
					CSA Certified  
					6HJ4-1/6HJ4-2  
					Terminal View  
					J Series  
					Voltage Selection  
					Unfiltered and Filtered Models  
					The most widely accepted of all the power entry modules,  
					the J series combines an IEC connector, 2-voltage, or 4-  
					voltage selection, and a North American fuseholder. It  
					features a compact snap-in design and a unique voltage  
					selector card.  
					J4 Models - This general purpose filter provides  
					susceptibility protection from line-to-ground noise on the  
					power line and acts as a high frequency “clean-up” filter for  
					more complex emissions applications.  
					HJ4 Models - This medical filter provides susceptibility  
					protection without the leakage current associated with line-  
					to-ground capacitors. Designed to allow equipment to  
					meet UL544 medical specifications for patient care and  
					non-patient care equipment, the HJ filter has a maximum  
					leakage current of 2µA at 120 VAC 60 Hz. See Appendix  
					C for more information on medical applications and UL  
					standards.  
					Open cover door and rotate fuse-pull lever to left. Select  
					operating voltage by orienting voltage selection card,  
					desired voltage on top left side. Push card firmly into  
					module slot. Rotate fuse-pull lever back into normal  
					position and re-insert fuse into holders. Use caution in  
					selecting correct fuse value.  
					Equipment rating labels and mounting clips for thicker  
					panel widths are available as accessories.  
					For more information on UL544 specifications, see  
					Appendix C.  
					Unfiltered Models  
					Note: When using the models with an IEC connector,  
					remember that the leakage current of the companion line  
					cord, GA400, is more significant than that of the filter -  
					which may disqualify this line cord from use in patient care  
					applications.  
					Available Voltage Selection  
					Part Number  
					6VJ1  
					6VJ1-2  
					Positions  
					4
					2
					Unfiltered Models  
					Available Voltage  
					Part Number  
					Selection  
					Positions  
					RFI Filter  
					Type  
					6VJ4  
					6J4-2  
					6HJ4-4  
					6HJ4-2  
					4
					2
					4
					2
					General Purpose1  
					General Purpose1  
					Medical2  
					Medical2  
					Note 1: General purpose filter for susceptibility applications  
					Note 2: Medical line filter for very low leakage UL544 health care requirements  
					114  
					Catalog 1654001  
					Revised 05-07  
					Dimensions are in inches and  
					millimeters unless otherwise  
					specified. Values in italics  
					are metric equivalents.  
					Dimensions are shown for  
					reference purposes only.  
					Specifications subject  
					to change.  
					USA Cust. Svc.: 1-800-468-2023  
					CORCOM Prods: 1-847-680-7400  
					www.corcom.com  
					www.tycoelectronics.com  
					Germany:  
					49-89-6089-0