4.0 - 10.0 GHz
SPECIFICATIONS, VZS/X-2776L1
Electrical
Environmental (Operating)
Ambient Temperature
Relative Humidity
Altitude
-10° to +40°C operating
Frequency
4.0 to 10.0 GHz
9ꢀꢄ non-condensing
Output Power
TWT
Flange
100 W min.
70 W min.
O P T I O N S :
Up to 10,000 ft (3000 m) witꢂ standard
adiabatic derating of 2°ꢁ1000 ft.
• Input Isolator
(-1 dB gain)
Gain (with no options)
44 dB min. at rated power output;
40 dB typ. at small signal
Shock and Vibration
Acoustic Noise
Designed to meet conditions normally
encountered in tꢂe laboratory
• Remote Control
Panel
RF Level Adjust
Gain Stability
0 to 20 dB continuous
6ꢀ dBA @ 3 ft. from amplifier
0.2ꢀ dBꢁ24 ꢂr maꢃ.
(at constant drive and temp.)
Mechanical
• 115 VAC
External Step-Up
Transformer
Cooling (TWT)
Forced air witꢂ integral blower.
Rear air intake and eꢃꢂaust.
Gain Variation
Input VSWR
12.0 dB pk-pk maꢃ., typ.
2.ꢀ:1 typ.
RF Input Connection
RF Output Connection
RF Output Monitor
Type N female
1.ꢀ:1 maꢃ. (witꢂ optional input isolator)
Type N female
Output VSWR
Load VSWR
2.ꢀ:1 typ.
Type-N female, -ꢀ7 dB nom.
1.ꢀ:1 maꢃ. for full spec compliance;
2.0:1 maꢃ. continuous operation;
any value witꢂout damage
Dimensions (W x H x D)
19 ꢃ ꢀ.2ꢀ ꢃ 24 in.
(483 ꢃ 133 ꢃ 610 mm)
Residual AM
-ꢀ0 dBc below 10 kHz;
-20 [1.3 + log F (kHz)] dBc,
10 kHz to ꢀ00 kHz;
Weight
Safety
70 lbs (32 kg)
EN61010
-80 dBc above ꢀ00 kHz
Phase Noise
Meets IESS-308ꢁ309 witꢂ 3 dB margin
1ꢀ dB maꢃ.
Noise Figure
Harmonic Content
-3 dBc typical at lower band edge,
decreasing to -1ꢀ dBc typ. at upper
band edge
Primary Power
220-240 VAC 10ꢄ, single pꢂase,
47-63 Hz
Power Consumption
Inrush Current
1.4 kVA typ.
1.ꢀ kVA maꢃ.
200ꢄ maꢃ.
Certificate Number: 30515
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 234, ISSUE 1
03/08 PDF