Power Divider
The content of this specification may change without notification 7/01/09
Power Divider
Coaxial
Broadband Power Divider (SMA Connectors)
Frequency
Range
N-Way
Ins ertion
Loss
Isolation
Amplitude
Balance
Phase
Balanc
Power
Forward
(W)
Power
Reverse
(W)
Input
Output
VSWR
Size
L x W x H
(mm)
VSWR
P/
(GHz)
(dB)
(dB)
min
(
±dB)
(±°)
max
max
max
JXWBGF-T-2 -500-2000-2
JXWBGF-T-4-500-2000
JXWBGF-T-8-500-2000
JXWBGF-T-2-800-2000
JXWBGF-T-4 -800-2000-2
JXWBGF-T-6-800-2000
JXWBGF-T-8-800-2000
JXW BGF-T-16-800-2000
JXWBGF-T-2 -800-2500-2
JXWBGF-T-4-800-2500
JXWBGF-T-6-800-2500
JXWBGF-T-8-800-2500
JXW BGF-T-16-800-2500
JXW BGF-T-2-1000-4000
JXW BGF-T-4-1000-4000
JXW BGF-T-8-1000-4000
JXW BGF-T-2-2000-8000
JXW BGF-T-3-2000-8000
JXW BGF-T-4-2000-8000
JXW BGF-T-6-2000-8000
JXW BGF-T-8-2000-8000
JXWBGF-T-12-2000-8000
JXWBGF-T-2-4000-18000
JXWBGF-T-4-4000-18000
0.5-2
0.5-2
0.5-2
0.8-2.0
0.8-2.0
0.8-2.0
0.8-2.0
0.8-2.0
0.8-2.5
0.8-2.5
0.8-2.5
0.8-2.5
0.8-2.5
1-4
2
4
0. 5
1. 0
1. 5
0. 5
0. 8
1. 6
1. 4
2. 0
0. 5
0. 8
1. 9
1. 2
2. 0
0. 5
0. 8
1. 5
0. 8
1. 0
1. 4
1. 8
1. 9
2. 3
0. 8
1. 6
20
20
20
20
20
18
18
18
20
20
18
20
18
20
20
20
20
18
18
18
18
18
18
18
0.2
0.3
0.3
0.2
0.4
0.5
0.6
0.8
0.2
0.4
0.9
0.4
0.8
0.3
0.3
0.4
0.3
0.6
0.4
1.0
0.7
1.0
0.4
0.5
2
3
3
3
6
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1.25
1.25
1.4
1.25
1.4
1.6
1.6
1.7
1.25
1.4
1.6
1.5
1.7
1.3
1.3
1.35
1.3
1.4
1.4
1.4
1.6
1.6
1.5
1.6
1.2
1.2
1.2
1.25
1.4
1.6
1.6
1.7
1.25
1.4
1.6
1.5
1.7
1.2
1.2
1.25
1.2
1.3
1.3
1.3
1.3
1.3
1.5
1.5
54x28x10
76x56x10
103x108x10
33x39x10
46x66x10
92x86x10
57x120x10
77x221x10
38x42x14
48x60x14
90x92x14
68x118x 14
80x220x14
28x28x10
43x56x10
63x108x10
28x28x10
66.5x37. 5x10
50x56x10
88x83x10
63x108x10
88x159x10
36x24x10
60x50.5x10
8
2
4
6
8
1
1
2
16
2
4
4
8
4
6
8
16
2
1
2
1-4
4
4
4
4
-
1-4
8
2-8
2
2-8
3
2-8
4
4
6
7
7
5
8
2-8
6
2-8
8
2-8
12
2
4-18
4-18
4
Notes:
1. Operating Temperature: -55 ºC to +85 ºC, Storage Temperature: -55 ºC to +95 ºC.
2. Applications: Indoor, 0-95%RH.
3. Forward power is tested with the output VSWR 1.5:1 of the loads. The power handling will be cut down when
the output port connect with a high VSWR. Ensure the output VSWR<1.5, avoiding output port open or short.
4. The power handling capability is 10 watts when used as divider with the load VSWR<1.2, the power handling
down to 2 watts when used as combiner.
5. Ensure connectors to be in flat connection with outer connectors, suggest to use a torque wrench.
1
188 Technology Drive, Unit H, Irvine, CA 92618
Tel: 949-453-9888 Fax: 949-453-8889 Email: sales@aacix.com
American Accurate Components, Inc.