AZ830  
					POLARIZED DIP RELAY  
					SINGLE SIDE STABLE  
					FEATURES  
					• Low profile for compact board spacing  
					• DC coils to 48 VDC  
					• High sensitivity, 100 mW pickup  
					• Meets FCC Part 68.302 1500 V lightning surge  
					• Meets FCC Part 68.304 1000 V dielectric  
					• Life expectancy to 100 million operations  
					• High switching capacity, 60 W, 125 VA  
					• Fits standard 16 pin IC socket  
					• Epoxy sealed  
					• UL file E43203 (UL1950); CSA file LR 88413  
					GENERAL DATA  
					Life Expectancy  
					Mechanical  
					Electrical  
					Minimum operations  
					1 x 108  
					CONTACTS  
					1 x 105 at 2 A, 30 VDC or 1 A, 125 VAC  
					2 x 106 at 1 A, 30 VDC or .5 A, 125 VAC  
					(see table for additional figures)  
					Arrangement  
					DPDT (2 Form C)  
					Bifurcated crossbar contacts  
					Operate Time (typical) 3 ms at nominal coil voltage  
					Ratings  
					Resistive load:  
					Release Time (typical) 2 ms at nominal coil voltage  
					Max. switched power: 60 W or 125 VA  
					Max. switched current: 2 A  
					(with no coil suppression)  
					Max. switched voltage: 250 VDC or 300 VAC  
					Max. carry current: 3A  
					Capacitance  
					Contact to contact: 1.0 pF  
					Contact set to contact: 1.0 pF  
					Contact to coil: 2.0 pF  
					Rated Load  
					UL  
					2 A at 30 VDC  
					1 A at 120 VAC  
					Bounce (typical)  
					At 10 mA contact current  
					1.5 ms at operate N.O. side  
					2.5 ms at operate N.C. side  
					Material  
					Silver alloy, gold clad. Silver palladium, gold clad  
					available upon request (not recommended for  
					current greater than 1 Amp).  
					Dielectric Strength  
					(at sea level)  
					1500 Vrms contact to coil  
					1000 Vrms between contact sets  
					1000 Vrms across contacts  
					Meets FCC Part 68.302 lightning surge  
					Meets FCC Part 68.304 V dielectric  
					Resistance  
					< 50 milliohms initially  
					COIL  
					Insulation Resistance 1000 megohms min. at 20°C, 500 VDC,  
					50% RH  
					Power  
					At Pickup Voltage  
					(typical)  
					Standard coil: 200 mW  
					Sensitive coil: 100 mW  
					Dropout  
					Greater than 10% of nominal coil voltage  
					Ambient Temperature At nominal coil voltage  
					Max. Continuous  
					Dissipation  
					1.0 W at 20°C (68°F)  
					0.9 W at 40°C (104°F)  
					Operating  
					Storage  
					Standard: -40°C (-40°F) to 70°C (158°F)  
					Sensitive: -40°C (-40°F) to 85°C (185°F)  
					Both: -40°C (-40°F) to 105°C (221°F)  
					Temperature Rise  
					Standard: 38°C (68°F) at nominal coil voltage  
					Sensitive: 21°C (38°F) at nominal coil voltage  
					Vibration  
					0.062" (1.5 mm) DA at 10–55 Hz  
					40 g  
					Temperature  
					Max. 115°C (239°F)  
					Shock  
					Enclosure  
					P.B.T. polyester  
					Tinned copper alloy, P.C.  
					270°C (518°F)  
					NOTES  
					Terminals  
					1. All values at 20°C (68°F).  
					2. Relay may pull in with less than “Must Operate” value.  
					3. Relay has fixed coil polarity.  
					4. For complete isolation between the relay’s magnetic fields, it is  
					recommended that a .197" (5.0 mm) space be provided between  
					adjacent relays.  
					Max. Solder Temp.  
					Max. Solder Time  
					Max. Solvent Temp.  
					5 seconds  
					80°C (176°F)  
					5. Relay adjustment may be affected if undue pressure is exerted  
					on relay case.  
					Max. Immersion Time 30 seconds  
					6. Specifications subject to change without notice.  
					Weight  
					5 grams  
					ZETTLER electronics GmbH  
					Junkersstrasse 3, D-82178 Puchheim, Germany  
					Tel. +49 89 800 97 0  
					Fax +49 89 800 97 200  
					office@ZETTLERelectronics.com  
					www.ZETTLERelectronics.com  
					2003-08-14