RWR

型号:

RWR

描述:

男子便携式雷达告警接收机[ Man Portable Radar Warning Receiver ]

品牌:

FILTRONIC[ FILTRONIC COMPOUND SEMICONDUCTORS ]

页数:

7 页

PDF大小:

3463 K

Man Portable Radar  
Warning Receiver  
For Covert and U.A.V.  
Applications  
Figure 1 RWR Unit  
Introduction  
The unit is designed for Radar Warning Receiver (RWR) applications where small size and low power  
consumption are of prime importance, with filtering, amplification, detection and frequency  
measurement being combined into one multi-function unit.  
Figure 2 shows a block diagram of the RWR and its three integral RF modules. Two amplitude  
measurement channels allow direction finding by amplitude comparison between adjacent antennas.  
One of these channels is also used in standby mode for detecting the presence of signals by polling  
round the antennas. A two-tier discriminator, fed from one of the amplitude channels via an SPDT  
switch, performs frequency measurement. Frequency resolution is nominally 160 MHz over an 8 to 18  
GHz band.  
Video  
Linear  
Output  
Amplifier  
Limiting  
Amplifier  
N
Trigger  
S
IFM  
Inputs  
E
Digital  
DLVA  
Data Out  
W
Bandpass  
Filter  
Video  
Output  
Figure 2: Radar Warning Receiver Block Diagram  
Filtronic Components Ltd., Airedale House, Royal London Industrial Estate, Acorn Park, Shipley,  
West Yorkshire, BD17 7SW, United Kingdom.  
Tel: +44 (1274) 531602 Fax:+44 (1274) 539724 Email: sales@fcl.com  
Page 1 of 1  
Man Portable Radar Warning Receiver  
Electrical Specifications  
Operating temperature range 0ºC to 70ºC  
Characterised at 25ºC.  
Table 1: Electrical Specifications  
Parameter  
Amplitude Module  
Frequency Module  
8 to 18 GHz  
-43 to –5 dBm 1  
150 MHz nom.  
<200 MHz r.m.s.  
100 ns  
Operating Frequency  
8 to 18 GHz  
Operating Dynamic Range  
Frequency Measurement Resolution  
Frequency Measurement Accuracy  
Minimum Pulse Width  
-73 to 0dBm  
-
-
-
-
-
Triggering  
External Command  
<100 ns max.  
-
Trigger to Data Delay  
Out of Band Rejection  
d.c. to 7 GHz > 60 dB  
20 to 26 GHz > 30 dB  
Tangential Signal Sensitivity (8 dB Video SNR)  
Logging Range  
-73 dBm  
-70 to -30 dBm  
±2.5 dB  
-
-
-
-
Frequency Flatness (Video)  
Amplitude Tracking (Between any Two Modules at the  
Same Frequency and Temperature)  
±1 dB  
Typical  
Video Rise Time  
30ns Typ 70 ns Max  
50 mV/dB  
±1 dB  
-
Video Output Slope  
-
Logging Linearity  
-
Video Coupling  
Active d.c. restored  
50 %  
-
Maximum Duty Cycle  
RF Input Switch Isolation  
RF Input Switch Speed  
RF Input Switch Control  
Insertion Gain RF Input to RF Output  
Insertion Ripple  
-
>30 dB Typ  
<5 µs  
TTL  
>30 dB Typ  
<5 µs  
TTL  
27dB nominal  
±2dB  
-
Input Return Loss  
7dB min (10dB typ)  
Power Supply Current (operating - no rf)  
+6 V at 130 mA  
-6 V at 50 mA  
+6 V at 200 mA  
-6 V at 30 mA  
Power Supply Current (standby)  
+6 V at 50 mA  
-6 V at 50 mA  
+6 V at 120 mA  
-6 V at 30 mA  
Power-up Time (standby to on)  
Power-up Time (cold start)  
Dimensions  
<100 µs  
<30ms  
<100 µs  
<2ms  
4 x 1 x 0.25 inches  
4 x 2 x 0.25 inches  
101.6 x 25.4 x 6.35 mm  
101.6 x 50.8 x 6.35 mm  
Weight 2  
50 grams  
85 grams  
Microwave Input Connector  
SSMA Female  
Dynawave  
1
2
not including amplitude module gain  
plus 10 grams for the interconnect module  
Filtronic Components Ltd., Airedale House, Royal London Industrial Estate, Acorn Park, Shipley,  
West Yorkshire, BD17 7SW, United Kingdom.  
Tel: +44 (1274) 531602, Fax: +44 (1274) 539724, Email: sales@fcl.com  
Page 2 of 2  
Man Portable Radar Warning Receiver  
System Timing  
The operation of the frequency measurement unit is as follows:  
When r.f. enters the discriminator circuits, the video voltages settle after a delay  
depending on the video bandwidth. The video signals are then stable and can be  
digitised by the comparators and ASIC. This digitization takes a maximum of 15 ns  
(ASIC worst case timing). Therefore valid raw frequency data is available 75 ns after  
the leading edge of the r.f. pulse. The raw frequency data is decoded in the EPROM  
look-up table which takes 55 ns.  
Figure 3: System Timing Diagram  
r.f.  
trfhld  
video out  
tlatch  
LATCH  
tlpw  
tdig  
tlhold  
Raw Data  
tdechold  
tdecode  
Data Valid  
Frequency Data Out  
tmeas  
Table 2: Timing  
Description  
symbol min max units  
time between latch edge and trailing edge of r.f trfhld  
6
60  
5
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
time from leading edge of r.f. and latch edge  
Width of latch pulse  
tlatch  
tlpw  
time to digitise video  
tdig  
15  
10  
55  
7
time from latch disable and raw data invalid  
time to decode raw frequency data  
time to hold decoded frequency data  
time from start of r.f. to valid frequency out  
tlhold  
tdecode  
tdechold  
tmeas  
130  
The LATCH signal holds the digitised frequency data when it is in the logic high  
state. When the LATCH signal is low, the digitising circuits are transparent and the  
data buses may change state rapidly increasing current consumption, thus to reduce  
this effect the latch signal should be held high and digitising initiated by a narrow  
logic low pulse. In order to capture 100 ns pulses the rising edge of the LATCH signal  
must occur no later than 94 ns after the start of the r.f. pulse.  
Filtronic Components Ltd., Airedale House, Royal London Industrial Estate, Acorn Park, Shipley,  
West Yorkshire, BD17 7SW, United Kingdom.  
Tel: +44 (1274) 531602, Fax: +44 (1274) 539724, Email: sales@fcl.com  
Page 3 of 3  
Man Portable Radar Warning Receiver  
Application Information  
The Amplitude Measurement Module and the Frequency Measurement Module are  
designed to be used together as the front end for a Radar Warning Receiver. The  
configuration described here has two Amplitude Modules facilitating direction of  
approach measurement from 4 directional antennae. If desired, only one Amplitude  
Module can be used in conjunction with an omni directional antenna forming a simple  
Radar Warning Receiver for simple classification of the threat signal. The unused  
input ports must be terminated with 50loads.  
Both modules feature a power saving standby mode that turns off the bias to the  
microwave amplifiers. The power supply can be removed completely for better  
power efficiency but there is a penalty to pay in start-up time as the modules  
incorporate switch mode DC-DC converters that take time to stabilise. The amplitude  
module also incorporates a CW removal circuit which can take up to 30ms to  
stabilise.  
The frequency measurement module requires an externally generated latch signal to  
hold the frequency data word on the digital output. This can be derived from the  
amplitude measurement video output or from some other source. The responsibility  
for generating the latch rests with the application circuit. Refer to figure 3 for timing  
information for the latch generation.  
Options and Future Developments  
Other configurations may be possible, e.g., SMA connectors instead of SSMA,  
custom outline, different logging range, etc. In addition Filtronic is developing this  
product further to provide extended frequency range and a back end control system to  
integrate the trigger, direction of approach and emitter characterisation functions.  
Please contact the factory for further details.  
While every effort is made to ensure the accuracy this release, please check with the  
factory for the latest information.  
Filtronic Components Ltd., Airedale House, Royal London Industrial Estate, Acorn Park, Shipley,  
West Yorkshire, BD17 7SW, United Kingdom.  
Tel: +44 (1274) 531602, Fax: +44 (1274) 539724, Email: sales@fcl.com  
Page 4 of 4  
Man Portable Radar Warning Receiver  
Typical Performance Data  
Figure 5: Log plot at 13 GHz  
Figure 4: Log plot at 8 GHz  
Figure 6: Log plot at 18 GHz  
Figure 7: Frequency Flatness at –50dBm input  
Figure 9: Frequency accuracy - CW  
Figure 8: Cell size distribution - CW  
Figure 11: Frequency accuracy – 100ns pulse  
Figure 10: Cell size distribution – 100ns pulse  
Filtronic Components Ltd., Airedale House, Royal London Industrial Estate, Acorn Park, Shipley,  
West Yorkshire, BD17 7SW, United Kingdom.  
Tel: +44 (1274) 531602, Fax: +44 (1274) 539724, Email: sales@fcl.com  
Page 5 of 5  
Man Portable Radar Warning Receiver  
Connector Details  
The Frequency Measurement Module connector is a 15 way Nanonics® Dualobe®  
single row receptacle. The mating part is a 15 way single row plug with wire leads.  
Example part number: SSM015PC2DC012N  
Table 4: Frequency Measurement Module Connector Designations  
Pin  
1
2
3
4
Type  
Signal  
+6V  
+6V  
-6V  
DGND  
Input Select  
POWER  
POWER  
POWER  
POWER  
IN TTL  
5
6
7
8
9
10  
11  
12  
13  
14  
15  
OUT TTL  
OUT TTL  
OUT TTL  
OUT TTL  
OUT TTL  
OUT TTL  
IN TTL  
IN TTL  
POWER  
POWER  
D0  
D1  
D2  
D3  
D4  
D5  
Trigger  
Standby (active low)  
GND  
GND  
The Amplitude Measurement Module connector is a 9 way Nanonics® Dualobe®  
single row receptacle. The mating part is a 9 way single row plug with wire leads.  
Example part number: SSM009PC2DC012N  
Table 5: Amplitude Measurement Module Connector Designations  
Pin  
1
2
3
4
Type  
Signal  
+6V  
+6V  
-6V  
POWER  
POWER  
POWER  
GND  
Power Ground  
Antenna Select  
Standby (active low)  
Digital Ground  
Video Output  
Video Ground  
5
6
7
8
IN TTL  
IN TTL  
GND  
OUTPUT  
GND  
9
The mating connectors are available from:  
Nanonics® Corporation  
Call (623) 581-6188 or Fax (623) 581-8242  
21644 North 14th Ave., Phoenix, Arizona 85027-2840  
email: info@nanonics.com  
www.nanonics.com  
Filtronic Components Ltd., Airedale House, Royal London Industrial Estate, Acorn Park, Shipley,  
West Yorkshire, BD17 7SW, United Kingdom.  
Tel: +44 (1274) 531602, Fax: +44 (1274) 539724, Email: sales@fcl.com  
Page 6 of 6  
Man Portable Radar Warning Receiver  
Figure 12: Outline and fixing details  
© Filtronic Components Ltd – All rights reserved. Unauthorised reproduction prohibited.  
Man Portable Radar Warning Receiver - rev 1.1 - March 2001  
Specifications subject to variation without notice. Check with factory for latest.  
E&OE  
Filtronic Components Ltd., Airedale House, Royal London Industrial Estate, Acorn Park, Shipley,  
West Yorkshire, BD17 7SW, United Kingdom.  
Tel: +44 (1274) 531602, Fax: +44 (1274) 539724, Email: sales@fcl.com  
Page 7 of 7  
厂商 型号 描述 页数 下载

TOKO

RWR-151208N2 [ Variable Inductor, Unshielded, DIP-6 ] 2 页

TOKO

RWR-151308N0 [ Variable Inductor, Unshielded ] 2 页

TOKO

RWR-151308N2 [ Variable Inductor, Unshielded, DIP-6 ] 2 页

TOKO

RWR-271208N2 [ Variable Inductor, Unshielded, DIP-6 ] 2 页

TOKO

RWR-271308N2 [ Variable Inductor, Unshielded, DIP-6 ] 2 页

TOKO

RWR-331208N2 [ Variable Inductor, Unshielded, DIP-6 ] 2 页

TOKO

RWR-331308N0 [ Variable Inductor, Unshielded ] 2 页

TOKO

RWR-361208N2 [ Variable Inductor, Unshielded, DIP-6 ] 2 页

TOKO

RWR-361308N2 [ Variable Inductor, Unshielded ] 2 页

TOKO

RWR-361412N2 [ Variable Inductor, Unshielded, DIP-6 ] 2 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.212665s