					POINT MATCH TOLERANCE  
					The standard leaded thermistors are calibrated and tested at 25°C to a tolerance of ± 5% or ± 10%; however, tighter tolerance,  
					point matched thermistors are readily available as are special point match temperatures to fit your application.  
					Since these thermistors have only one controlled point of reference ( the point match temperature ), the resistance at other  
					temperatures is given by the "Resistance VS Temperature Conversion Tables" for the appropriate material curve. The resistance  
					value at any temperature is the ratio factor times the resistance at 25°C.  
					Example: 1M1002-5, +70°C resistance = (Resistance factor for curve 1 at 70°C is .1990) X (10000 ohm resistance at 25°C)  
					= 1990 ohms.  
					The tolerance of the resistance at any temperature is described by Figure 2.  
					FIGURE 2  
					POINT MATCH TOLERANCES VS. TEMPERATURE  
					Point match resistance tolerances at temperatures other than  
					MAX. R VS. T  
					25ºC are not the same as the calibration temperature. This  
					difference is presented in Figure 2.  
					MIN. R VS. T  
					The tolerance at any given temperature is the point match  
					NOMINAL R VS. T  
					tolerance + the MT ±% (Manufacturing Tolerance).  
					The MT ±% may be obtained from the R vs. T Conversion  
					tables and is added to the point match temperature, i.e., ±  
					1% Tol. at 25ºC + ± 2.6% at -30ºC for Curve 1 equals a total  
					tolerance of ± 3.6% at -30ºC.  
					PIVOT POINT  
					(CALIBRATION TEMPERATURE)  
					25°C  
					TEMPERATURE  
					COMPUTER AIDS FOR THERMISTOR SELECTION  
					A spreadsheet is available for the Vishay Thermistor Materials that calculates Beta, Steinhart-Hart Equation Constants A, B,  
					and C, the resistance at any temperature based upon the Steinhart constants or Beta, the temperature equivalent of the  
					resistance reading, and resistance temperature coefficients.  
					This spread sheet will also calculate the total resistance tolerance of any point matched thermistor for temperatures in 10ºC  
					increments, and the resistance tolerance at any temperature within the calibrated range of curve tracking thermistors. Please  
					contact factory if interested in this Excel™ spreadsheet.  
					Document Number: 33003  
					Revision 11-Feb-02  
					www.vishay.com  
					21  
					For technical questions, contact thermistor1@vishay.com