ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Apr. 07, 2011
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Part Number Explanation
x R SB – 40 U xx x
1
2
3
4
5
6 7
1---Replace”x” with “S” to indicate SMT package, or “0” to indicate through hole package
2---RoHS 6, change “R” to “7” means RoHS 5
3---Series name, 1/16 Brick
4---Series code
5---Input range (18-75V)
6---Output voltage, V2=1.2Vout, V5=1.5Vout, V8=1.8Vout, 02=2.5Vout, 03=3.3Vout, 05=5.0Vout, 12=12Vout
7---Option, “x” of the model part number to be 0-9, A-Z, which will represent the special request of
customer.
Absolute Maximum Ratings
Unit
Parameter
Input Voltage (continuous)
Input Transient Voltage
Remote On/Off
Min
-0.3
-
Typ
Max
80
Notes
-
-
-
-
-
-
V
V
100
18
100mS maximum
-0.3
-
V
I/O Isolation Voltage
Ambient Temperature
Storage Temperature
1500
85
V
-40
-55
C
C
125
Note: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may
permanently damage the device.
Input Specifications
Parameter
Min
Typ
Max
Unit
Notes
Input Voltage
Input Current (full load)
Vo=1.2 V - 1.8 V
18
48
75
V
-
-
-
-
-
-
2.5
3.0
3.5
A
A
A
Vo=2.5 V - 3.3 V
Vo=5.0 V - 12 V
Input Current (no load)
-
-
60
1
120
3
mA
mA
Remote Off Input Current
Tested with simulated source
impedance of 15 uH, 5 Hz to 20 MHz;
use a 100 uF/100 V electrolytic
capacitor with ESR=1 ohm max at 200
kHz at the input.
Input Reflected Ripple Current
(pk-pk)
-
-
20
3
50
7
mA
mA
Input Reflected Ripple Current
(rms)
Input Over Voltage Lockout
I2t Inrush Current Transient
Turn-on Voltage Threshold
Turn-off Voltage Threshold
78
-
-
82
V
A2s
V
0.01
17.2
16.8
0.02
17.8
17.4
16.6
16.2
V
Note: All specifications are typical at nominal input, full load at 25 C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com
2