IWD505-3V

型号:

IWD505-3V

品牌:

BEL[ BEL FUSE INC. ]

页数:

3 页

PDF大小:

119 K

IWD SERIES - DUAL OUTPUT, 10 WATT  
DESCRIPTION  
FEATURES  
• 5V and 12V Inputs  
• Input Pi Filter  
• 6-Sided Shielding  
• Wide Input Voltage  
• 500V Isolation  
IWD dual output DC/DC converters offer excellent • Industry Standard Package  
regulation and isolation in an industry-standard package. • Industry Standard Pinout  
Available in 5V and 12V input versions, the IWD is • 85°C Case Operation  
perfect for industrial, datacom, or telecom applications. • Short Circuit Protection  
The IWD features short-circuit protection and 500 VDC  
isolation. Please see the IWS and IAS series for single  
output applications.  
Efficiency vs. Load (5V Input)  
90  
85  
80  
75  
70  
65  
60  
55  
50  
EFF. IWD505  
EFF. IWD512  
TECHNICAL SPECIFICATIONS  
Input  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
LOAD %  
Voltage Range  
5 VDC Nominal  
12 VDC Nominal  
4.5 - 9 VDC  
9 - 18 VDC  
Reflected Ripple  
Max.  
20% Iin  
Reverse Input Current  
100% Iin Max.  
Efficiency vs. Load (12V Input)  
90  
Output  
85  
80  
75  
70  
65  
60  
55  
Setpoint Accuracy  
1%  
1.0% Vout  
1.0% Vout  
Line Regulation Vin Min. - Vin Max., Iout Rated  
Load Regulation Iout Min. - Iout Max., Vin Nom.  
Minimum Output Current  
Rated  
10 % Iout  
EFF. IWD1209  
EFF. IWD1212  
Dynamic Regulation, Loadstep  
Pk Deviation  
25% Iout  
1% Vout  
500 µs  
0.02%/°C  
Settling Time  
Temperature Coefficient  
1% Vout nom.  
Ripple and Noise, 20 MHz BW  
10  
20  
30  
40  
50  
60  
70  
80  
90 100  
LOAD %  
1
Short Circuit Protection  
Current Limit  
Hiccup  
130%  
General  
Notes  
Switching Frequency  
Isolation  
300 kHz  
1
Converter will auto-restart once fault has been removed.  
Input - Output  
500 VDC  
Specifications typically at 25°C, normal line, and full load, unless otherwise  
stated.  
9
Isolation Resistance - Input to Output  
Standard Case Operating Range  
Industrial Range (add -I to p/n)  
Storage Range  
Humidity Max., Non-Condensing  
Vibration, 3 Axes, 5 min each  
Safety  
10 Ohms  
-25 to +85°C  
-40 to +85°C  
-40 to +125°C  
95%  
5 g, 10 - 55 Hz  
UL, cUL, TUV  
1.4 oz  
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with  
commercial wave-soldering equipment.  
Safety: Agency approvals may vary from model to model. Please consult  
factory for specific model information.  
Weight (approx.)  
REV. 12/01  
1
IWD SERIES - DUAL OUTPUT, 10 WATT  
MODELS - (See the last page of section for options.)  
INPUT VOLTAGE  
(VOLTS)  
INPUT VOLTAGE  
RANGE (VOLTS)  
MAXIMUM INPUT  
CURRENT (AMPS)*  
OUTPUT  
VOLTAGE (VOLTS)  
RATED OUTPUT  
CURRENT (AMPS)  
RIPPLE & NOISE  
pk-pk (mV)  
TYPICAL  
EFFICIENCY**  
MODEL  
IWD505  
IWD512  
IWD515  
IWD1205  
IWD1212  
5
5
5
12  
12  
4.65 - 5.50  
4.65 - 5.50  
4.65 - 5.50  
10.90 - 13.20  
10.90 - 13.20  
3.20  
3.20  
3.20  
1.55  
1.55  
5
1.000  
0.500  
0.375  
1.000  
0.500  
50  
120  
150  
50  
82%  
80%  
82%  
80%  
84%  
12  
15  
5
12  
120  
NOTES:  
*
Maximum input current at minimum input voltage, maximum rated output power.  
** At nominal V , rated output.  
in  
MECHANICAL DRAWING  
Tolerances  
Inches:  
.XX 0.040  
.XXX .010  
(Millimeters)  
.X 1.0  
.XX 0.25  
Pin  
Function  
Thermal Impedance  
Natural convection  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
15.4 °C/W  
12.2 °C/W  
9.3 °C/W  
7.4 °C/W  
6.4 °C/W  
1
2
3
+Vin  
-Vin  
+ Vout  
Common  
Pin:  
0.002  
0.05  
4
5
Case:  
+ 0.04, - 0.00  
- Vout  
Note:  
+ 1.0, - 0.0  
Thermal impedance data is dependent on  
many environmental factors. The exact  
thermal performance should be validated  
for specific application.  
(Tolerances as listed unless otherwise  
specified.)  
2
OPTIONS  
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer  
and add them to the model number. Example ordering options are located below the options table.  
OPTION  
Negative Logic  
SUFFIX  
APPLICABLE SERIES  
REMARKS  
N
HAS, HBD, HBS, HES, HLS, HLD, LES,  
QBS, QES, QLS, TES, TQD  
TTL "Low" Turns Module ON  
TTL "High" Turns Module OFF  
Lucent-Compatible Trim  
T
HAS, HBD, HBS, HES, HLS, QBS, QES,  
QLS  
Terminal Strip  
Trim  
TS  
1
XWS, XWD, XWT  
IAS, LES  
Enable  
2
IAD, IAS, LES, SMS  
IAS, LES  
Trim and Enable  
3
Pin Length and Heatsink Options  
0.110" (2.8mm) Pin Length  
Standard Pin Length is 0.180" (4.6mm)  
8
9
All Leaded Models  
All Leaded Models  
0.150" (3.8mm) Pin Length  
0.24" (6.1mm) Horizontal Heatsink  
1H  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
0.24" (6.1mm) Vertical Heatsink  
0.45" (11.4mm) Horizontal Heatsink  
0.45" (11.4mm) Vertical Heatsink  
0.95" (24.1mm) Horizontal Heatsink  
0.95" (24.1mm) Vertical Heatsink  
1V  
2H  
2V  
3H  
3V  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
Example Options:  
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.  
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.  
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional President  
of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date  
manufactured. Specifications are subject to change without notice.  
REV. AUG 16, 2002  
3
厂商 型号 描述 页数 下载

POWER-ONE

IWD IWD系列 - 双输出, 10瓦[ IWD SERIES - DUAL OUTPUT, 10 WATT ] 3 页

POWER-ONE

IWD1205 IWD系列 - 双输出, 10瓦[ IWD SERIES - DUAL OUTPUT, 10 WATT ] 3 页

BEL

IWD1205 [ DC-DC Regulated Power Supply Module, 2 Output, 10W, Hybrid ] 2 页

BEL

IWD1205-1H [ DC-DC Regulated Power Supply Module, 2 Output, 10W, Hybrid ] 3 页

BEL

IWD1205-1V [ DC-DC Regulated Power Supply Module, 2 Output, 10W, Hybrid ] 3 页

BEL

IWD1205-1V-I [ DC-DC Regulated Power Supply Module, 2 Output, 10W, Hybrid ] 3 页

BEL

IWD1205-2H [ DC-DC Regulated Power Supply Module, 2 Output, 10W, Hybrid ] 3 页

BEL

IWD1205-2H-I [ DC-DC Regulated Power Supply Module, 2 Output, 10W, Hybrid ] 3 页

BEL

IWD1205-2V [ DC-DC Regulated Power Supply Module, 2 Output, 10W, Hybrid ] 3 页

BEL

IWD1205-2V-I [ DC-DC Regulated Power Supply Module, 2 Output, 10W, Hybrid ] 3 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.219270s