AZ830  
					POLARIZED DIP RELAY  
					SINGLE SIDE STABLE  
					FEATURES  
					• Low profile for compact board spacing  
					• DC coils to 48 VDC  
					• High sensitivity, 96 mW pickup  
					• Life expectancy to 100 million operations  
					• High switching capacity, 60 W, 125 VA  
					• Fits standard 16 pin IC socket  
					• Epoxy sealed for automatic wave soldering and cleaning  
					• Meets FCC Part 68.302 1500 V lightning surge  
					• Meets FCC Part 68.304 1000 V dielectric  
					• UL file E43203 (UL1950)  
					GENERAL DATA  
					Life Expectancy  
					Mechanical  
					Electrical  
					Minimum operations  
					1 x 108  
					1 x 105 at 2 A, 30 VDC or 1 A, 125 VAC  
					2 x 106 at 1 A, 30 VDC or .5 A, 125 VAC  
					(see table for additional figures)  
					CONTACTS  
					Operate Time (typical) 3 ms at nominal coil voltage  
					Arrangement  
					DPDT (2 Form C)  
					Bifurcated crossbar contacts  
					Release Time (typical) 2 ms at nominal coil voltage  
					(with no coil suppression)  
					Ratings  
					Resistive load:  
					Max. switched power: 60 W or 125 VA  
					Max. switched current: 2 A  
					Max. switched voltage: 250 VDC or 300 VAC  
					Max. carry current: 3A  
					Capacitance  
					Contact to contact: 1.0 pF  
					Contact set to contact: 1.0 pF  
					Contact to coil: 2.0 pF  
					Bounce (typical)  
					At 10 mA contact current  
					1.5 ms at operate N.O. side  
					2.5 ms at operate N.C. side  
					Rated Load  
					UL  
					2 A at 30 VDC  
					1 A at 120 VAC  
					Dielectric Strength  
					(at sea level)  
					1500 Vrms contact to coil  
					1000 Vrms between contact sets  
					1000 Vrms across contacts  
					Meets FCC Part 68.302 lightning surge  
					Meets FCC Part 68.304 V dielectric  
					Material  
					Silver alloy, gold clad.  
					< 50 milliohms initially  
					Resistance  
					COIL  
					Insulation Resistance 1000 megohms min. at 20°C, 500 VDC,  
					50% RH  
					Power  
					Dropout  
					Greater than 10% of nominal coil voltage  
					At Pickup Voltage  
					(typical)  
					Standard coil: 200 mW  
					Sensitive coil: 100 mW  
					Ultra-Sensitive coil: 96 mW  
					Ambient Temperature At nominal coil voltage  
					Operating  
					Storage  
					Standard: -40°C (-40°F) to 70°C (158°F)  
					Max. Continuous  
					Dissipation  
					1.0 W at 20°C (68°F)  
					0.9 W at 40°C (104°F)  
					Sensitive: -40°C (-40°F) to 85°C (185°F)  
					Ultra-Sensitive: -40°C (-40°F) to 90°C (194°F)  
					All: -40°C (-40°F) to 115°C (239°F)  
					Temperature Rise  
					Standard: 38°C (68°F) at nominal coil voltage  
					Sensitive: 21°C (38°F) at nominal coil voltage  
					Ultra-Sensitive: 16°C (29°F) at nominal coil voltage  
					Vibration  
					0.062" DA at 10–55 Hz  
					40 g  
					Shock  
					Temperature  
					Max. 115°C (239°F)  
					Enclosure  
					P.B.T. polyester  
					Tinned copper alloy, P.C.  
					270°C (518°F)  
					5 seconds  
					NOTES  
					Terminals  
					1. All values at 20°C (68°F).  
					2. Relay may pull in with less than “Must Operate” value.  
					3. Relay has fixed coil polarity.  
					Max. Solder Temp.  
					Max. Solder Time  
					Max. Solvent Temp.  
					4. For complete isolation between the relay’s magnetic fields, it is  
					recommended that a .197" (5.0 mm) space be provided between  
					adjacent relays.  
					5. Relay adjustment may be affected if undue pressure is exerted  
					on relay case.  
					80°C (176°F)  
					Max. Immersion Time 30 seconds  
					Weight 5 grams  
					6. Specifications subject to change without notice.  