PowerLink Single Jacket PV Cable
PowerLink Dual Jacket PV Cable
The PowerLink Single Jacket PV Cable is designed for interconnection wiring
of grounded or ungrounded photovoltaic power systems as described in section
690.31 (A) and other applicable parts of the National Electric Code, NEC, NFPA70,
and RoHS compliant.
The PowerLink Dual Jacket PV Cable is designed for interconnection wiring of
grounded or ungrounded photovoltaic power systems as described in section
690.31 (A) and other applicable parts of the National Electric Code, NEC, NFPA70,
RoHS compliant.
Our
superior
single
jacket design allows the
outside of the cable to be
smaller than a standard
dual jacket PV cable.
By using only one jacket
the cable is narrower
making the termination of
a connector much easier.
Product Features and Benefits:
Product Features and Benefits:
• Conductors: Bare copper, tinned copper, aluminum
• Sizes: 18AWG - 6AWG
• Conductors: Bare copper, tinned copper, aluminum
• Sizes: 18AWG - 6AWG
• Stranding: 7 or 19
• Stranding: 7 or 19
• Insulation: XLPE (ASTM D2863)
• Colors: Black, white, red, blue, green, yellow, orange
• Sunlight resistant
• Insulation: XLPE (ASTM D2863) white or black
• Jacket: PVC (ASTM D2863) black
• Sunlight resistant
• Direct burial rated
• Direct burial rated
• Electrical Characteristics
• Electrical Characteristics
Voltage rating
Temp rating (wet or dry)
Spark test
600V
90°C
2000V
90°C
5kV
Voltage rating
Temp rating (wet or dry)
Spark test
600V
90°C
2000V
90°C
5kV
1500V
-40°C
VW-1
1500V
-40°C
VW-1
Cold bend
-40°C
VW-1
Cold bend
-40°C
VW-1
Flammability
Flammability
• UL4703 rated, file #E327886
• UL4703 type PV wire, file #E3227886
PowerLink USE-2 and Thermoset Cable
PowerLink Dual Rated Cable
The PowerLink USE-2 andThermoset Cable is a single jacket cable used for lighting
and power applications and may be installed in raceway, duct, direct burial, and
aerial installations. The
The PowerLink Dual Rated Halogen free photovoltaic cables are used as
interconnecting wiring for photovoltaic power systems. This one cable is UL/
TUV rated. UL1581,
cable meets National
IEC60332-1, IEC61034,
Electric Code and other
IEC60754,
ISO4892,
EN-
general purpose wiring
IEC60811-
applications.
Satisfies
2-1, UL Sub 1703,
UL4703 Type PV,
2PfG1169/08.2007,
USE-2, RHH, RHW-2
XHH, XHHW, XHHW-
2, RHW, RHW-2, RHH,
R90, RW75, RW90,
RWU75, RWU90. (UL),
(cUL), (cULus).
IEC61215,
RoHS
2002/95/EC.
Product Features and Benefits:
Product Features and Benefits:
• Conductors: Bare copper, tinned copper, aluminum
• Sizes: 14AWG - 6AWG
• Sizes: 8AWG - 14AWG
• Conductors: Tinned copper
• Stranding: Per TUV requirements
• Insulation: XLPE
PowerLink Dual Rated Cable
ꢀ
PartꢀNumberꢀ
AWGꢀ
Voltage/Certification
• Stranding: 7 or 19
HCPBH2D1
HCPBH4D1
HCPBH6D1
HCPBH8D1
14AWG
12AWG
10AWG
8AWG
1000v TUV/1000v UL
1000v TUV/1000v UL
1000v TUV/1000v UL
1000v TUV/1000v UL
• Insulation: XLPE (ASTM D2863)
• Sunlight resistant
• Jacket: XLPE
• Direct burial rated
• Direct burial rated
Call your local rep for additional PowerLink
dual rated cable part numbers
• Electrical Characteristics
• Sunlight resistant
Voltage rating
Temp rating (wet or dry)
Spark test
600V
90°C
1000V
90°C
5kV
• Electrical Characteristics
Voltage rating
1000V (TUV) / 600V (UL) 1000V (TUV) / 1000V (UL)
1500V
-40°C
VW-1
Temp rating (wet or dry) 90°C
90°C
Cold bend
-40°C
FT-1
Spark test
6,000 VAC
VW-1, (UL1581, UL44)
10,000 VAC
Flammability
Flammability
2000V also available