VDE  
					SMALL SIZED  
					POWER RELAY  
					JZ-RELAYS  
					14  
					.551  
					FEATURES  
					22  
					.866  
					• Small sized flat type: 22×14×11.6 mm .866×.551×.457 inch  
					• High dielectric withstanding: 10,000 V surge in µs between coil and contact  
					• High electrical noise immunity  
					11.6  
					.457  
					• High sensitivity type available  
					• VDE,TÜV, SEMKO also approved  
					mm inch  
					SPECIFICATIONS  
					Contact  
					Characteristics  
					(at 25°C 77°F, 50% Relative humidity)  
					Standard  
					type  
					High  
					Standard  
					TV-5 High  
					Max. operating speed  
					Initial insulation resistance*1 Min. 100 MΩ at 500 V DC  
					20 cpm  
					Type  
					sensitivity type TV-5 type sensitivity type  
					Arrangement  
					1 Form A  
					Between open  
					contacts  
					750 Vrms for 1 min.  
					2,000 Vrms for 1 min.  
					Min. 10,000 V  
					Initial  
					Contact material  
					Silver alloy  
					breakdown  
					Initial contact resistance, max.  
					(By voltage drop 6 V DC 1 A)  
					Between  
					contacts and coil  
					voltage*2  
					100 mΩ  
					5 A 125 V AC 3 A 125 V AC 8 A 125 V AC 8 A 125 V AC  
					5 A 30 V DC 3 A 30 V DC 5 A 30 V DC 5 A 30 V DC  
					Surge voltage between  
					contact and coil*3  
					Nominal switching capacity  
					Rating  
					(resistive)  
					Max. switching power  
					150 W, 750 VA 90 W, 500 VA 150 W, 1,250 VA 150 W, 1,000 VA  
					Operate time*4  
					(at nominal voltage)  
					Release time*4  
					(without diode)  
					Approx. 4 ms  
					Max. switching voltage  
					250 V AC, 110 V DC (0.3 A)  
					Max. switching current  
					5 A  
					105  
					3 A  
					8 A  
					Approx. 2 ms  
					Mechanical (at 180 cpm)  
					Expected  
					life (min.  
					5 × 106  
					(at nominal voltage)  
					2 ×105  
					105  
					5 ×104  
					Temperature rise  
					(ambient temperature at  
					70°C)  
					Max. 45°C  
					at max. switching current  
					Electrical  
					(at 20 cpm)  
					(at nominal (3 A 125 V AC) (at nominal (8 A 125 V AC)  
					operating  
					capacity)  
					105  
					operating  
					capacity)  
					105  
					operations)  
					(3 A 30 V DC)  
					(5 A 30 V DC)  
					Functional*5  
					Min. 98 m/s2 {10 G}  
					Min. 980 m/s2 {100 G}  
					98 m/s2 {10 G}, 10 to 55 Hz at  
					double amplitude of 1.6 mm  
					Shock  
					Coil (at 20°C 68°F)  
					Standard type  
					Destructive*6  
					Functional*7  
					resistance  
					Nominal operating power  
					Nominal operating power  
					400 mW  
					200 mW  
					High sensitivity type  
					Vibration  
					117.6 m/s2 {12 G}, 10 to 55 Hz  
					at double amplitude of 2 mm  
					resistance  
					Remarks  
					Destructive  
					* Specifications will vary with foreign standards certification ratings.  
					*1 Measurement at same location as "Initial breakdown voltage" section  
					*2 Detection current: 10mA  
					Conditions for operation, Ambient  
					–40°C to +70°C  
					–40°F to +158°F  
					transport and storage*8  
					(Not freezing and condens-  
					ing at low temperature)  
					temp.  
					*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981  
					*4 Excluding contact bounce time  
					Humidity  
					5 to 85% R.H.  
					*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs  
					*6 Half-wave pulse of sine wave: 6ms  
					Unit weight  
					Approx. 7 g .25 oz  
					*7 Detection time: 10µs  
					*8 Refer to 5. Conditions for operation, transport and storage mentioned in  
					AMBIENT ENVIRONMENT (Page 24).  
					TYPICAL APPLICATIONS ORDERING INFORMATION  
					• Microwave oven (fan, inside lamp)  
					Ex. JZ  
					1a  
					F
					S
					9 V  
					TV  
					• Machineries which need electrical  
					noise resistance and surge resistance,  
					(Ex. hot-water heater)  
					Contact  
					Protective  
					arrangement construction  
					Coil voltage  
					(DC)  
					Type classification  
					Type classification  
					1a: 1 Form A F: Flux-resistant Nil: Standard  
					5, 6, 9, 12, Nil: UL/CSA/VDE  
					type  
					recognized type  
					(400 mW)  
					S: High sensitivity  
					(200 mW)  
					18, 24 V  
					TV: TV-5 rated type  
					Note: Standard packing Carton: 100 pcs. Case: 500 pcs.  
					UL/CSA, TV-5 (only for TV type) approved type is standard.  
					62