HL (AZH)  
					CAUTIONS  
					Common for all types  
					1. There are limits to what type of environment can be tolerated.  
					This limit switch is designed under the premise that it will be used in a standard industrial device. Accordingly, there are limits as to  
					what can be tolerated if used outdoors or where water and oil, etc., may get on the device. The following table indicates how much  
					water and oil can be withstood (classification of protective structure).  
					Plastic case (AZH1*)  
					Die casting case (AZH2*)  
					Protective classification  
					Testing method  
					IP64  
					IP67  
					No harmful effect when sprayed with water for 10 minutes from  
					all angles.  
					Water does not enter product after immersion in water 1m deep  
					for 30 minutes.  
					Cannot be used outdoors or in a place where water and oil, etc., Cannot be used outdoors where it can be rained on directly and  
					will continually contact the device. cannot be used submersed in water or in oil, etc.  
					Limits on use  
					Note: Although, initially, the protective classification complies under the testing above, due consideration must be taken because great differences may result depending  
					on factors such as duration of operation, installation method, and environment.  
					2. The internal mechanism will break if the actuator is moved beyond its Total-travel (T.T.). Always use within the T.T.  
					Die casting case  
					1) Do not expose HL limit switch to hot  
					water (over 60°C 140°F) and in a water  
					vapor environment.  
					2) Avoid the place where organic sol-  
					vents, strong acid, strong alkali liquid  
					and vapor may attach to the products  
					directly. Prevent using the HL limit switch  
					in place where inflammable or corrosive  
					gas will be generated.  
					3) Do not change the operating position  
					by bending the actuator.  
					4) Use within an ambient temperature of  
					–10 to 80°C. (However, do not allow it to  
					freeze.)  
					5) If OT is too big, the life of limit switch  
					will be shortened by switching friction.  
					Use it with enough margin of OT. 70% of  
					OT standard value will be good.  
					6) Attach the terminal cover securely to  
					the body with the metal stop latch to the  
					projection of the body.  
					9) When used outdoors (in places where  
					there is exposure to direct sunlight or  
					rain such as in multistory car parks) or in  
					environments where ozone is generated,  
					the influence of these environments may  
					cause deterioration of the rubber materi-  
					al. Please consult us if you intend to use  
					a switch in environments such as these.  
					10) Avoid use in excessively dusty envi-  
					ronments where actuator operation  
					would be hindered.  
					7) Confirmation test in the actual applica-  
					tion is highly recommended.  
					8) Do not use the switch in a silicon  
					atmosphere. Care should be taken  
					where organic silicon rubber, adhesive,  
					seling material, oil, grease or lead wire  
					generates silicon.  
					Plastic case  
					1) Do not use in water or oil. Do not  
					place the switch where it is always  
					exposed to water or dust splash.  
					2) Do not expose HL limit switch to hot  
					water (over 60°C 140°F) and in a water  
					vapor environment.  
					3) Avoid the place where organic sol-  
					vents, strong acid, strong alkali liquid  
					and vapor may attach to the products  
					directly. Prevent using the HL limit switch  
					is place where inflammable or corrosive  
					gas will be generated.  
					6) If OT is too big, the life of limit switch  
					will be shortened switching friction. Use it  
					with enough margin of OT. 70% of OT  
					standard value will be good for use.  
					7) Attach the terminal cover securely to  
					the body to the extent you can identify  
					the clicking or locking sound.  
					in environments where ozone is generat-  
					ed, the influence of these environments  
					may cause deterioration of the rubber  
					material. Please consult us if you intend  
					to use a switch in environments such as  
					these.  
					11) Avoid use in excessively dusty envi-  
					ronments where actuator operation  
					would be hindered.  
					8) A confirmation test in the actual appli-  
					cation is highly recommended.  
					9) Do not use the switch in a silicon  
					atmosphere. Case should be taken  
					where organic silicon rubber, adhesive,  
					sealing material, oil, grease or lead wire  
					generates silicon.  
					4) Do not change the operating position  
					by bending the actuator.  
					5) Use within an ambient temperature of  
					–10 to 80°C. (However, do not allow it to  
					freeze.)  
					10) When used outdoors (in places  
					where there is exposure to direct sunlight  
					or rain such as in multistory car parks) or  
					All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.