DL (AZD1)  
					Open and close the cover Mounting  
					For the adjustable roller arm type, the  
					cover will not open and close since it  
					contacts the adjustable arm. Either  
					extend the arm fully or remove the arm,  
					then open or close the cover. Also, the  
					same is true of the variable rod types  
					(AZD1007 and AZD1057).  
					1) When mounting, use washers (to pre-  
					•ꢀMountingꢀdimensions  
					vent loosening) and tighten at a torque of  
					0.49ꢀtoꢀ0.69ꢀN•mꢀ{5ꢀtoꢀ7ꢀkg•cm}.  
					2) To securely mount the switch, not only  
					fasten the main switch body only with  
					2-4.2+0.2 dia. holes or  
					M4 tapped holes  
					220–2  
					.8660-.079  
					0
					two mounting holes, but also provide two  
					+0.2  
					−0.35  
					4
					mm dia. and max. 5 mm .197 inc high  
					47± 0.1  
					1.850±.004  
					projections and insert them into the holes  
					on the bottom of the main switch body.  
					+0.2  
					–0.35  
					2-4  
					dia. and  
					max. 5mm high  
					Projections  
					Adjustable Rod Length  
					To adjust the length of the variable rod,  
					slightly loosen the hex. nut that is secur-  
					ing the rod and then change the length.  
					After making the change, tighten the hex.  
					nut keeping within a tightening torque of  
					22± 0.1  
					.866±.004  
					M4 screw  
					0.98 and 1.37 N•m. Over tightening  
					might damage the rod presser plate.  
					Projection  
					CAUTIONS  
					(Terminal with insulating grip)  
					mm inch  
					11) To protect against entry of foreign  
					matter from the outside, we recommend  
					sealing as much as possible using con-  
					duit connectors.  
					12) Avoid use in excessively dusty envi-  
					ronments where actuator operation  
					would be hindered.  
					1) This model uses silver terminals.  
					Therefore, if used at relatively low fre-  
					quencies for long periods of time, or if  
					used with very small loads, the oxidiza-  
					tion that forms on the contact surfaces  
					will not wear away and eventually cause  
					improper contact. For such applications,  
					use limit switches with gold/metal con-  
					tacts (e.g. VL limit switches) or ones  
					meant for small loads (e.g. HL limit  
					switches).  
					8 min.  
					.315  
					8 min.  
					.315  
					8 min.  
					.315  
					3.7 to 4.2  
					dia.  
					.146 to  
					.165  
					3.7 to 4.2  
					dia.  
					.146 to  
					.165  
					3.7 to 4.2  
					.146 to .165  
					12 min.  
					.472  
					12 min.  
					.472  
					12 min.  
					.472  
					(
					)
					(
					)
					For N.C.  
					For N.O.  
					32  
					13) When used outdoors (in places  
					where there is exposure to direct sunlight  
					or rain such as in multistory car parks) or  
					in environments where ozone is generat-  
					ed, the influence of these environments  
					may cause deterioration of the rubber  
					material. Please consult us if you intend  
					to use a switch in environments such as  
					these.  
					14) Do not store in places where organic  
					gas might be generated or in places of  
					high dust content or high humidity.  
					15) Since the roller section of the roller  
					arm (50 mm dia. rubber roller type)  
					(AZD1003 and AZD1053) is heavy, the  
					contacts may reverse due to inertia of  
					the roller section which easily leads to  
					erroneous operation.  
					When crimp terminals  
					are used.  
					16  
					1.260  
					.630  
					8) When wiring, do not connect the lead  
					wires directly to the terminals, but use the  
					crimp terminals and tighten them to a  
					2) This switch is not designed for under-  
					water use. Do not use the unit under-  
					water.  
					torque of 0.39 to 0.59 N•m {4 to 6 kg·cm}.  
					3) Do not use the switch where it may  
					come in direct contact with organic sol-  
					vents, strong acids, strong alkaline liq-  
					uids or stream, or in atmospheres con-  
					taining flammable or corrosive gases.  
					4) For the arm type (roller arm type,  
					adjustable roller arm type), the arm can  
					only be set at 15° interval.  
					5) To improve reliability during actual  
					use, it is recommended that the opera-  
					tion be checked under installation condi-  
					tions.  
					9) After wiring, when attaching the cover  
					to switch body, be careful that the cover  
					to switch body, be careful that the cover  
					seal rubber is set normaly on it and tight-  
					en the screw to a torque of 0.20 to 0.39  
					N
					•
					m {2 to 4 kg·cm}. If tighten the screw  
					strongly, the thread is broken.  
					0) Safety mechanism is adopted which  
					1
					secures positive break under such abnormal  
					conditions like contact welding, spring break,  
					etc. In case of using the safety mechanism  
					which breaks welded N.C. contact, conform  
					to the conditions as shown below.  
					(For the value below of adjustable rod, the  
					length of the rod shows the value when  
					length of rod is set at 26 mm same as the  
					roller arm. The value of adjustable roller  
					arm (50 dia. rubber roller) type shows the  
					value when arm length is set at 40 mm.)  
					If there is a possibility of exposure to  
					shock, please make considerations for  
					safety, for example, by providing a  
					redundant circuit so that danger can be  
					avoided in the event that the contacts  
					reverse and cause erroneous operation.  
					6) If O  
					will be shortened switching friction. Use it  
					with enough margin of O T.. 70% of O T.  
					.T. is too big, the life of limit switch  
					.
					.
					standard value will be good for use.  
					7) Do not use the switch in a silicon  
					atmosphere. Case should be taken  
					where organic silicon rubber, adhesive,  
					sealing material, oil, grease or lead wire  
					generates silicon.  
					Actuator  
					mevement force (Min.)  
					Required  
					Approx.  
					Approx.  
					3.5mm  
					mm inch  
					Push plunger  
					Roller plunger  
					Adaptable crimp terminal  
					29.4 N  
					(Bare terminal)  
					.138 inch  
					8 min.  
					8 min.  
					.315  
					8 min.  
					.315  
					Roller arm  
					Adjustable rod  
					Adjustable roller arm  
					.315  
					3.7 to 4.2  
					dia.  
					3.7 to 4.2  
					dia.  
					Approx. 45°  
					9.8 N  
					6.4 N  
					3.7 to 4.2  
					.146 to .165  
					.146 to  
					.146 to  
					.165  
					.165  
					(50 dia. rubber roller) Approx. 45°  
					Approx.  
					10 min.  
					.394  
					10 min.  
					.394  
					10 min.  
					.394  
					Roller lever type  
					7 mm  
					19.6 N  
					.276 inch  
					10/2010  
					39