TX-S
2. Specifications
Characteristics
Item
Specifications
Arrangement
2 Form C
Initial contact resistance, max.
Max. 100 mΩ (By voltage drop 6 V DC 1A)
Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Contact
Contact material
Nominal switching capacity
Max. switching power
1 A 30 V DC (resistive load)
30 W (DC) (resistive load)
110V DC
Max. switching voltage
Rating
Max. switching current
1 A
Min. switching capacity (Reference value)*1
10μA 10mV DC
Single side stable
2 coil latching
50 mW (3 to 12 V DC), 70 mW (24 V DC)
70 mW (3 to 12 V DC), 150 mW (24 V DC)
Nominal operating
power
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section.
750 Vrms for 1min. (Detection current: 10mA)
Between open contacts
Breakdown voltage
(Initial)
Between contact and coil
Between contact sets
Between open contacts
1,800 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160μs) (FCC Part 68)
Surge breakdown
voltage (Initial)
Electrical
characteristics
Between contacts and coil 2,500 V (2×10μs) (Telcordia)
Max. 50°C
Temperature rise (at 20°C 68°F)
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Functional
Shock resistance
Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10μs.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 5 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Mechanical
Min. 5×107 (at 180 cpm)
Min. 2×105 (1 A 30 V DC resistive) (at 20 cpm)
Expected life
Electrical (Standard contact)
Ambient temperature: –40°C to +70°C –40°F to +158°F;
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Unit weight
20 cpm
Approx. 2 g .071 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. AgPd contact type is available for low level load switching (10V DC, 10mA max. level).
*2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
REFERENCE DATA
1. Maximum switching capacity
2. Life curve
3. Mechanical life
Tested sample: TXS2-4.5V, 10 pcs.
Operating speed: 180 cpm
100
90
DC resistive load
(cos = 1)
30V DC
resistive load
φ
80
100
10
Pick-up voltage
70
Max.
Min.
1.0
60
50
0.5
0.4
40
Drop-out voltage
30
0.3
Max.
Min.
0.2
20
10
0
30
100
0
0.5
1.0
Switching current, A
200
10
100
1,000 5,000
No. of operations, ×104
Contact voltage, V
ASCTB15E 201407-T