TX-S  
					2. Specifications  
					Characteristics  
					Item  
					Specifications  
					Arrangement  
					2 Form C  
					Initial contact resistance, max.  
					Max. 100 mΩ (By voltage drop 6 V DC 1A)  
					Standard contact: Ag+Au clad,  
					AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)  
					Contact  
					Contact material  
					Nominal switching capacity  
					Max. switching power  
					1 A 30 V DC (resistive load)  
					30 W (DC) (resistive load)  
					110V DC  
					Max. switching voltage  
					Rating  
					Max. switching current  
					1 A  
					Min. switching capacity (Reference value)*1  
					10μA 10mV DC  
					Single side stable  
					2 coil latching  
					50 mW (3 to 12 V DC), 70 mW (24 V DC)  
					70 mW (3 to 12 V DC), 150 mW (24 V DC)  
					Nominal operating  
					power  
					Insulation resistance (Initial)  
					Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section.  
					750 Vrms for 1min. (Detection current: 10mA)  
					Between open contacts  
					Breakdown voltage  
					(Initial)  
					Between contact and coil  
					Between contact sets  
					Between open contacts  
					1,800 Vrms for 1min. (Detection current: 10mA)  
					1,000 Vrms for 1min. (Detection current: 10mA)  
					1,500 V (10×160μs) (FCC Part 68)  
					Surge breakdown  
					voltage (Initial)  
					Electrical  
					characteristics  
					Between contacts and coil 2,500 V (2×10μs) (Telcordia)  
					Max. 50°C  
					Temperature rise (at 20°C 68°F)  
					(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)  
					Operate time [Set time] (at 20°C 68°F)  
					Release time [Reset time] (at 20°C 68°F)  
					Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)  
					Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)  
					(without diode)  
					Functional  
					Shock resistance  
					Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10μs.)  
					Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)  
					10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)  
					10 to 55 Hz at double amplitude of 5 mm  
					Destructive  
					Mechanical  
					characteristics  
					Functional  
					Vibration resistance  
					Destructive  
					Mechanical  
					Min. 5×107 (at 180 cpm)  
					Min. 2×105 (1 A 30 V DC resistive) (at 20 cpm)  
					Expected life  
					Electrical (Standard contact)  
					Ambient temperature: –40°C to +70°C –40°F to +158°F;  
					Conditions for operation, transport and storage*2  
					Max. operating speed (at rated load)  
					Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
					Conditions  
					Unit weight  
					20 cpm  
					Approx. 2 g .071 oz  
					Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the  
					actual load. AgPd contact type is available for low level load switching (10V DC, 10mA max. level).  
					*2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.  
					REFERENCE DATA  
					1. Maximum switching capacity  
					2. Life curve  
					3. Mechanical life  
					Tested sample: TXS2-4.5V, 10 pcs.  
					Operating speed: 180 cpm  
					100  
					90  
					DC resistive load  
					(cos = 1)  
					30V DC  
					resistive load  
					φ
					80  
					100  
					10  
					Pick-up voltage  
					70  
					Max.  
					Min.  
					1.0  
					60  
					50  
					0.5  
					0.4  
					40  
					Drop-out voltage  
					30  
					0.3  
					Max.  
					Min.  
					0.2  
					20  
					10  
					0
					30  
					100  
					0
					0.5  
					1.0  
					Switching current, A  
					200  
					10  
					100  
					1,000 5,000  
					No. of operations, ×104  
					Contact voltage, V  
					ASCTB15E 201407-T  
					–3–