TX-S  
					3) 2 coil latching (L2, LT)  
					Nominal operating  
					current  
					[10%] (at 20C 68F)  
					Coil resistance  
					[10%] (at 20C 68F)  
					Nominal operating  
					power  
					Nominal coil  
					voltage  
					Set voltage  
					(at 20C 68F)  
					Reset voltage  
					(at 20C 68F)  
					Max. applied voltage  
					(at 20C 68F)  
					Set coil  
					46.7mA  
					23.3mA  
					15.6mA  
					11.7mA  
					7.8mA  
					Reset coil  
					46.7mA  
					23.3mA  
					15.6mA  
					11.7mA  
					7.8mA  
					Set coil  
					32.1  
					129  
					Reset coil  
					32.1  
					Set coil  
					Reset coil  
					1.5V DC  
					3V DC  
					129  
					4.5V DC  
					6V DC  
					289  
					289  
					80%V or less of  
					nominal voltage*  
					(Initial)  
					80%V or less of  
					nominal voltage*  
					(Initial)  
					70mW  
					70mW  
					150%V of  
					nominal voltage  
					514  
					514  
					9V DC  
					1,157  
					2,057  
					3,840  
					1,157  
					2,057  
					3,840  
					12V DC  
					24V DC  
					5.8mA  
					5.8mA  
					6.3mA  
					6.3mA  
					150mW  
					150mW  
					*Pulse drive (JIS C 5442-1986)  
					2. Specifications  
					Characteristics  
					Item  
					Specifications  
					Arrangement  
					2 Form C  
					Max. 100 m (By voltage drop 6 V DC 1A)  
					Initial contact resistance, max.  
					Contact  
					Standard contact: Ag+Au clad, AgPd contact (low level load): AgPd+Au clad (stationary),  
					AgPd (movable)  
					Contact material  
					Nominal switching capacity  
					Max. switching power  
					1 A 30 V DC (resistive load)  
					30 W (DC) (resistive load)  
					110V DC  
					Max. switching voltage  
					Max. switching current  
					Min. switching capacity (Reference value)*1  
					1 A  
					Rating  
					10A 10mV DC  
					Single side stable  
					50 mW (1.5 to 12 V DC), 70 mW (24 V DC)  
					35 mW (1.5 to 12 V DC), 50 mW (24 V DC)  
					70 mW (1.5 to 12 V DC), 150 mW (24 V DC)  
					Nominal operating  
					1 coil latching  
					power  
					2 coil latching  
					Insulation resistance (Initial)  
					Between open contacts  
					Min. 1,000M (at 500V DC)  
					Measurement at same location as “Initial breakdown voltage” section.  
					750 Vrms for 1min. (Detection current: 10mA)  
					1,800 Vrms for 1min. (Detection current: 10mA)  
					1,000 Vrms for 1min. (Detection current: 10mA)  
					1,500 V (10160s) (FCC Part 68)  
					Breakdown voltage  
					Between contact and coil  
					(Initial)  
					Between contact sets  
					Between open contacts  
					Between contacts and coil  
					Surge breakdown  
					voltage (Initial)  
					Electrical  
					characteristics  
					2,500 V (210s) (Telcordia)  
					Max. 50C  
					Temperature rise (at 20C 68F)  
					(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)  
					Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce  
					time.)  
					Operate time [Set time] (at 20C 68F)  
					Release time [Reset time] (at 20C 68F)  
					Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce  
					time.) (without diode)  
					Functional  
					Shock resistance  
					Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10s.)  
					Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)  
					10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.)  
					10 to 55 Hz at double amplitude of 5 mm  
					Destructive  
					Mechanical  
					characteristics  
					Functional  
					Vibration resistance  
					Destructive  
					Mechanical  
					Electrical  
					Min. 5107 (at 180 cpm)  
					Min. 2105 (1 A 30 V DC resistive) (at 20 cpm)  
					Expected life  
					Ambient temperature: –40C to +70C –40F to +158F;  
					Conditions for operation, transport and storage*2  
					Max. operating speed (at rated load)  
					Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
					Conditions  
					Unit weight  
					20 cpm  
					Approx. 2 g .071 oz  
					*1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual  
					load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level].)  
					*2 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.  
					ds_61022_en_txs: 060213D  
					3